Choosing a Concrete Mix for Commercial Work
A mix design is a recipe with four numbers that matter most to owners: strength, water ratio, slump and air. Each one answers a different question about how the concrete will perform.

Strength in psi
The compressive strength the concrete must reach at 28 days. Footings may need 3,000 psi, slabs 4,000 and columns 5,000 or more. Higher is not always better, since very high strength can be more brittle and costs more.
Water-cement ratio
The ratio of water to cement by weight is the best predictor of durability. Lower is denser and tighter. Many commercial slabs specify 0.45 or lower, and de-iced pavements 0.40.
Slump
A simple test of how workable the mix is. Pumped concrete is usually 4 to 6 inches, stiff slab mixes 3 to 5. Water should never be added at the truck to raise slump, because it raises the water ratio, which weakens the concrete. Water reducers add flow without it.
Air content
Tiny air bubbles let water expand as it freezes. Anywhere concrete freezes it should be air-entrained, usually around 5 to 7 percent, and more where de-icing salts are used.
Use the Mix Chooser
The Mix Chooser tool shows typical strength, water ratio, slump and air for twelve common jobs and four exposure conditions.
Use the Mix Chooser
Services that go with this
Structure and FoundationsSlab on GradeThe floor slab that everything else sits on
Floors, Docks and FlatworkConcrete Parking LotsLong-lasting lots that stay flat
Cutting, Demolition and SpecialtyConcrete Testing and InspectionProof that the concrete in the form is what you orderedNo service matches that search. Try a shorter word.
Questions about your project?
Tell us about the project: the city, the kind of concrete work and when you need it. You get a plain written bid, and a person answers the phone at (800) 290-5816.